Autoclave Time

Autoclave Time

Autoclave Time

For sterilization in autoclave devices, temperature, humidity time and pressure affect sterilization processes. It will be possible to sterilize between 10 and 20 minutes in a pre-vacuum autoclave under 1 atmosphere pressure at 121 degrees, between 20 and 45 minutes in an autoclave without pre-vacuum, or between 4 and 5 minutes in a pre-vacuum autoclave with 2 atmospheres at 134 degrees.

How Many Degrees Should the Autoclave Degree Be?
Sterilization is generally done at 121 degrees in the autoclave device. In the autoclave device that has reached this temperature, the autoclaving time may vary depending on the volume of the material to be sterilized and the way the autoclave is filled.

What is Autoclave Device?
Devices used for the purification of microorganisms on or in the material to be sterilized are called autoclave devices. After the sterilization process, viruses, bacteria, fungi and all similar microorganisms are completely destroyed on the materials. Various substances and tools can be used while performing these sterilization processes. One of the most effective tools to be used in the sterilization process is autoclave devices. For this reason, autoclave devices can be used in environments such as hospitals.

What Does Autoclave Device Do?
The first models of the autoclave device are in the form of a pressure cooker. Inspired by the steam engines made by Denis Papin in 1681, it continues to develop these devices with the autoclave device invented by Charles Chamberland in the field of Microbiology.

What Are the Parts of the Autoclave Device?
Autoclave devices have some necessary parts to work properly. So what are these sections? You may be wondering. Autoclave devices consist of 7 parts. We can list these sections as follows;

boiler section
cover section
Thermostat
air vent cock
pressure regulation valve
Manometer
Thermometer
The basic parts of autoclave devices appear as we mentioned above. Almost all of the autoclave devices have these sections. Thanks to these parts of the autoclave devices, the sterilization processes of the materials can be done much more easily. These devices are generally used in environments such as hospitals for sterilization processes. However, it would not be correct to limit it only in this way. You can witness that autoclave devices are used in many areas.